- Compact-Panel 1000 x 600 x 18 mm - building biologically tested FERMACELL fibre-reinforced 18 mm gypsum panel, IBR-Quality Seal (Institute for Healthy Building, Rosenheim). The positioning of the specially milled pipe channels ensures Variomodul pipe spacing of 10 cm and simple installation.
- Variomodular-Pipe 11.6 x 1.5 mm ( 5 layer composite pipe)
- The Variomodular-Pipes are embedded in Kompakt filling material (Compact-Filling Compound), which guarantees optimum heat transmission.
Faster reaction times
The Compact-Floor Heating was subjected to comparative testing in a real situation with an floor heating system for cast plaster flooring (VarioRoll, pipe spacing 10 cm, screed cover of the Varioklima pipe: 4 cm) for a period of 24 hours.
Measurement process, diagram:
The following graph shows the measurement process, with the mean value of the respective surface temperature shown in summary form for purposes of clarity.
Evaluation:
It is easily recognisable that the surface of the Compact-Floor Heating heats up very quickly in comparison with the underfloor heating for cast plaster flooring. The reaction time of the surface temperatures to the fall in flow temperature is shorter.
. This ensures that the Compact-Floor Heating can be regulated more flexibly.
During heating operations the surface temperature level is above that of the underfloor heating for cast plaster flooring.
. This permits a more efficient utilisation of the heating area because lower flow temperatures are possible compared to other underfloor heating systems.
Compact-Floor Heating reacts considerably faster than underfloor heating systems for cast plaster and dry screed flooring.
Cross Section:
Compact-Panel:
A photo of our VarioComp production:
Compact Floor Heating prospect to download
(.pdf-document, 533 KB)