Vario - Pump Manifold Station

Combination of low-temperature surface heating with high-temperature heating system

Anyone who integrates a low-temperature surface heating system into existing high-temperature heating systems faces the problem of having to combine two different flow temperatures. Variotherm has developed a special pump manifold station: For example, existing radiators (design temperature approx. 60 °C) can be combined with a Variotherm surface heating system (approx. 30 °C).

The Pumped VarioManifold 5.0 is ideal when larger areas are to be equipped with floor heating in drywall construction or wall heating.

The hydraulics fit.

High and low temperature heating systems are often combined in attic conversions, bathroom renovations, and extensions to existing houses. Two to 15 low temperature heating circuits can be integrated into a Pumped VarioManifold 5.0. The thermometer clearly displays the temperatures in the heating circuit.

The Variotherm solution guarantees that the additional pump does not affect the existing hydraulics in any way. This means: Both the radiators and the surface heating can continue to deliver full performance!  

The Pumped VarioManifold 5.0 is an intelligent injection system: Depending on the need, it mixes either warm water from the high temperature supply into the surface heating circuit – or cool water from the low temperature return. The aluminium multi-layer composite pipes are connected to the ¾-inch Eurocone connections.  

1. Flow indicator primary circuit

2. Regulating valve

3. High-efficiency circulation pump

4. KFE cock, rotatable

5. Immersion sleeve for flow sensor

6. Thermometer

7. Manual air vent

8. Flow valve, adjustable with flow indicator

9. Electrical connection for pump (3 × 0.5 mm², 230V AC, 50 Hz)

10. Shut-off port valve (3/4" internal thread)

11. Variotherm compression fitting 3/4" Eurocone

12. Shut-off valve, thermoelectric actuator retrofittable

13. Weather-compensated control variant

14. Fixed value control variant

15. Insulating sleeve

16. Maximum temperature limiter

1 Flow Indicator Primary Circuit

2 Control Valve

3 High-Efficiency Circulation Pump

4 KFE Cock, rotatable

5 Immersion Sleeve for Supply Sensor

6 Thermometer

7 Manual Vent

8 Supply Valve, adjustable with Flow Indicator

9 Electrical Connection for Pump (3 × 0.5 mm², 230V AC, 50 Hz)

10 Shut-off port Valve (3/4" Internal Thread)

11 Variotherm Compression Fitting 3/4" Eurocone

12 Shut-off Valve, Thermoelectric Actuator retrofittable

13 Variant Weather-Controlled Regulation

14 Variant Fixed Value Regulation

15 Insulating Sleeve

16 Maximum Temperature Limiter

Practical advantages at a glance

Compact design for minimal space requirements 

Optional fixed value or weather-compensated control 

Optimal adjustment of the primary flow rate through integrated regulating valve 

Space-saving high-efficiency pump for the correct water quantity in the low-temperature circuit 

Standardized ¾-inch Eurocone connections for connecting the surface heating circuits 

Hydraulic balancing via flow rate valves 

Easy flushing and venting directly at the manifold