The heating circuit manifold for heating and cooling systems
The cooling and heating circuit manifold from Variotherm regulates the flow rate and distributes the water from your heat source (e.g., heat pump) evenly in the surface heating and cooling systems for floors, walls, and ceilings. This ensures that the rooms in your home are comfortably warm and pleasantly cool.
VarioManifold 5.0
Every house needs a Heating – and increasingly also a Cooling. Every Heating and Cooling, in turn, needs a reliable distribution system. Professional installers and builders appreciate the VarioManifold 5.0: its absolute reliability, quick Installation, and easy, individual regulation of the heating and cooling circuits.
VarioManifold 5.0
Every house needs a Heating – and increasingly also a Cooling. Every Heating and Cooling, in turn, needs a reliable distribution system. Professional installers and builders appreciate the VarioManifold 5.0: its absolute reliability, quick Installation, and easy, individual regulation of the heating and cooling circuits.
This is how the heating and cooling circuit distributor works.
Explained using the example of a heating circuit manifold: It consists of an equal number of supply and return connections, arranged on two manifold bars. From the heat source (e.g., heat pump), the water flows into the manifold system during heating with a flow temperature between 25 and 35 °C. This directs the warm water directly into the individual rooms. The water heats the rooms via the surfaces, cools down again, and flows back into the heating circuit manifold via the return. With the VarioManifold 5.0, the heating and cooling circuit manifold from Variotherm, up to 17 heating circuits can be connected. Thanks to its modular design, the VarioManifold 5.0 can also be expanded at any time with individual elements afterward.
The required flow rates of the circulating water in the individual heating circuits are adjusted via control valves, thus performing the hydraulic balancing. This ensures that it is evenly warm in every room.
The same process occurs with water-guided surface cooling for wall and ceiling.
The modular all-rounder
Space-saving. Flexible in installation. Precisely adjustable. Easy to clean. Expandable at any time. The Variotherm heating/cooling circuit manifold meets the highest professional standards and impresses in practice with many useful features.
The modular all-rounder
Space-saving. Flexible in installation. Precisely adjustable. Easy to clean. Expandable at any time. The Variotherm heating/cooling circuit manifold meets the highest professional standards and impresses in practice with many useful features.
Simple! Free in the installation
The individual segments are only 50 mm wide and 55 mm deep. This allows them to fit space-savingly into a manifold cabinet that is only 80 mm deep when installed. A true space marvel!
Simple! Free in the installation
The individual segments are only 50 mm wide and 55 mm deep. This allows them to fit space-savingly into a manifold cabinet that is only 80 mm deep when installed. A true space miracle!
Safe and accurate adjustment
The right setting leads to success! The orange fixing ring makes this very safe and easy. During commissioning, the optimal flow per heating and cooling circuit is set. Fix the ring and you're done. Once regulated, the control valve can be repositioned to the previously set value even after a possible closure. This fully complies with EN 1264-4.
Safe and precise adjustment
The right setting leads to success! The orange fixing ring makes this very safe and easy. During commissioning, the optimal flow per heating and cooling circuit is set. Fix the ring and you're done. Once regulated, the control valve can be repositioned to the previously set value even after a possible closure. This fully complies with EN 1264-4.
Flexible! Expandable at any time.
Thanks to its modular design, the VarioManifold 5.0 can be retrofitted with individual elements. Depending on the need, up to 17 heating/cooling circuits can be installed. The installation is carried out in the standard version as a 2-bar manifold, but installation in the form of a 1-bar manifold is also possible. Innovative and individual!
Flexible! Expandable at any time.
Thanks to its modular design, the VarioManifold 5.0 can be retrofitted with individual elements. Depending on the need, up to 17 heating/cooling circuits can be installed. The installation is carried out in the standard version as a 2-bar manifold – but installation in the form of a 1-bar manifold is also possible. Innovative and individual!
Clean! Easy to clean.
The transparent sight glass of the flow meter can be easily unscrewed and cleaned if necessary. This can be done during operation, under pressure. Cleaning ensures that the flow rate on the sight glass (liters per hour) can always be read clearly and distinctly. Clean solution!
Clean! Easy to clean.
The transparent sight glass of the flow meter can be effortlessly unscrewed and cleaned if necessary. This can be done under pressure during operation. Cleaning ensures that the flow rate on the sight glass (liters per hour) can always be read clearly and distinctly. Clean affair!
The VarioManifold simply explained
A heating and cooling circuit manifold regulates the flow rates of the water and distributes it evenly in the surface heating and cooling systems. This is the only way to keep it comfortable within your own four walls in summer and winter.
If a surface heating or cooling system is installed in a building, the installed heating pipes reach different lengths. This results in various pressure losses. The consequence: some rooms are heated or cooled better and others worse.
The solution: A distribution system regulates and distributes the heating and cooling capacity in a water-based surface heating and cooling system for floor, wall, and ceiling.
Technology and Installation
As with all Variotherm complete systems, special attention was paid to making the installation as quick and easy as possible in practice when developing the VarioManifold 5.0. The modern heating circuit manifold can be easily installed flush-mounted, discreetly disappearing into the wall and thus ensuring a tidy, harmonious room feel.
- 3 port valve with blind plug supply (1" internal thread)
- 3 port ball valve with blind plug return (1" internal thread)
- Manual air vent
- Thermometer
- KFE valve 1/2", rotatable
- Flow indicator, sight glass can be unscrewed under pressure
- Supply segment with adjustable flow indicator (10–160 l/h)
- Return segment with shut-off valve
- Thermoelectric actuator (for individual room control)
- Labeling tags
- End plate (insulated)
- Compression fitting 3/4" Eurocone (for pipes ø11.6, ø16, and ø20 mm)
- Insulating sleeve (optional for cooling case)
1 3-way ball valve with blind plug supply (1" internal thread)
2 3-way ball valve with blind plug return (1" internal thread)
3 Manual air vent
4 Thermometer
5 KFE valve 1/2", rotatable
6 Flow indicator, sight glass can be unscrewed under pressure
7 Supply segment with pre-adjustable flow indicator (10–160 l/h)
8 Return segment with shut-off valve
9 Thermoelectric Actuator (for individual room control)
10 Label tags
11 End plate (insulated)
12 Compression fitting 3/4" Eurocone (for pipes ø11.6, ø16, and ø20 mm)
13 Insulating sleeve (optional for cooling case)
Weather-controlled regulation
Perfect room temperature in any weather: The weather-controlled regulation is an alternative to manual temperature control. Depending on the outside temperature, the flow temperature is automatically adjusted. Available for the Pumped VarioManifold 5.0 and the Pump Microstation.
Weather-controlled regulation
Perfect room temperature in any weather: The weather-controlled regulation is an alternative to manual temperature control. Depending on the outside temperature, the flow temperature is automatically adjusted. Available for the Pumped VarioManifold 5.0 and the Pump Microstation.














![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/8/1/csm_MenueKomp_0379641585.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/f/7/csm_MenueFBH_fe4020f437.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/f/3/csm_MenueWHK_4a37cbe305.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/4/8/csm_MenueEasyWand_2d03039b41.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/d/3/csm_MenueDeckeM_757ab4d013.jpg)


![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/7/6/csm_MenueBKH_dae1bd9b36.jpg)



