For an even heat distribution and reliable function of the Floor Heating for dry construction, a suitable substrate is essential. A load-bearing, even, and dry structure, as well as the correct combination of the individual layers – from the leveling layer to the support systems to the final floor covering – are crucial.
Screed/Rough ceiling
Screed:
Check evenness, if necessary, level with leveling compound
Check dryness
Raw Ceiling:
Check evenness, if necessary, level with leveling compound
Building waterproofing, if necessary
Wood beam ceiling
Check deflection, evenness, and load-bearing capacity, strengthen construction if necessary.
Fillings/Drywall Construction
Filling:
Loose filling
Bound filling
Trickle protection fleece, if required
Load distribution layer necessary! e.g.:
20 mm dry screed element
2 x 15 mm OSB board, glued and screwed
2 x 19 mm chipboard, glued and screwed
VarioComp boards on thermal/acoustic insulation boards
up to 30 mm insulation thickness
Up to an insulation thickness of 30 mm, the VarioComp board can be laid directly on thermal/impact sound insulation. The prerequisite is a sufficiently high compressive strength of the underlay boards.














![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/2/4/csm_MenueKomp_0379641585.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/b/3/csm_MenueFBH_fe4020f437.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/6/1/csm_MenueWHK_4a37cbe305.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/2/3/csm_MenueEasyWand_2d03039b41.jpg)
![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/1/8/csm_MenueDeckeM_757ab4d013.jpg)


![[Translate to English:] [Translate to English:]](/fileadmin/_processed_/0/5/csm_MenueBKH_dae1bd9b36.jpg)